Display Selector
Ground Power and Bus Switching Panel
with associated APU Lights and Indicators
SOURCE OFF Light
Illuminated –
No source has been manually selected to power the related
Transfer Bus or the manually selected source has been
disconnected.
I
f a source has been selected to power the opposite
T
ransfer
B
us
then
both
T
ransfer
B
usses are powered.