Display Selector
Ground Power and Bus Switching Panel
with associated APU Lights and Indicators
APU LOW OIL PRESSURE Light
Illuminated –
D
uring start until the APU oil pressure is normal
O
il pressure is low causing an automatic shutdown (after
the start cycle is
complete).
I
f the light is illuminated when the APU switch is placed to
OFF, the light will
extinguish after 5 minutes.
The
light is disarmed when the APU switch is in the OFF
position.