Flight Control Panel
System A Flight Control Switch

STBY RUD -

Activates standby hydraulic system pump and opens standby
rudder shutoff valve to pressurize standby rudder power control
unit.

OFF -

Closes flight control shutoff valve isolating ailerons, elevators and
rudder from associated hydraulic system pressure.

ON (guarded position) -

Normal operating position.