TRIP RESET Switch
Push (if fault condition is corrected) –
- Resets the BLEED TRIP OFF, PACK and DUCT
OVERHEAT lights.
- The related engine bleed valve opens, or the related
pack valve opens, or the related air mix valve opens.
- The lights will remain illuminated until reset.