Illuminated –
When the thrust reverser is commanded to stow and extinguishes
10 seconds later when the isolation valve closes.
Any time the REVERSER light illuminates for more than
approximately 12 seconds, a malfunction has occurred and the
MASTER CAUTION and ENG system annunciator lights illuminate.
One or more of following has occurred:
- Isolation valve or thrust reverser control valve is not in the
commanded position.
- One or more thrust reverser sleeves are not in the
commanded state.
- The auto–restow circuit has been activated.
- A failure has been detected in the synchronization shaft
lock circuitry.