STANDBY POWER Switch
AUTO (guarded position) –
- In flight, or on the ground, and AC transfer busses powered:
- In flight, or on the ground, loss of all AC power
OFF (unguarded center position) –
- STANDBY PWR OFF light illuminates.
- AC standby bus, static inverter, and DC standby bus are not
powered.
BAT (unguarded position) –
- AC standby bus is powered by the battery through the static
inverter.
- DC standby bus and battery bus are powered
- directly by the battery.
|