Autoslats (Cont'd.)

Autoslat operation is normally powered by hydraulic system B. An alternate
source of power is provided by system A through a power transfer unit (PTU) if a
loss of pressure is sensed from the higher volume system B engine driven pump.
The PTU provides system A pressure to power a hydraulic motorized pump,
pressurizing system B fluid to provide power for the autoslat operation.